Conclusions from Constructability Meeting
The information provided below is not to be used for bidding or construction purposes.
- Cold Mix will not be allowed for bond breaker repair.
- Contractor will have option of High Early PCC @ access points.
- Allow 24' paving.
- No white topping on the shoulders.
- Allow string-less paving.
- Require the contractor to provide a minimum 8' roadway in each direction for local traffic regardless of either paving 12' at a time or 24' all at once.
- Payments for concrete will be: Labor by sq. yd. and material cu. yd.
- Joint spacing will be 6' x 6' panels and all sealed with small segments of different spacing and unsealed, as determined NDOR.
- Surfaced shoulders cannot be used as haul road.
|